Fluke 43B Power Quality Analyzer Maintain power systems, troubleshoot power problems, diagnose equipment failures The Fluke 43B Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems and diagnose equipment failures. All in a rugged handheld package. * New! NiMH Battery provides extended operating time of 6.5 hours * Combines the most useful capabilities of a power quality analyzer, multimeter and scope * Calculates 3-phase power on balanced loads, from a single-phase measurement * Trends voltage, current, frequency, power * * * * * * * * harmonics and captures voltage sags, transients and inrush current Monitoring functions help track intermittent problems and power system performance Records two selectable parameters for up to 16 days 20 measurement memories to save/recall screens and data with cursor readings FlukeView(R) Software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic Measures resistance, diode voltage drop, continuity, and capacitance Users/applications manual and power quality video to help answer tough questions Complete package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable 3 year warranty on the Fluke 43B, 1 year on accessories * On screen graphics show you how to set up 3-phase power measurements * Watts, power factor, displacement power factor (Cos ), VA and VAR * Voltage and current waveforms * Voltage and current waveforms * True-rms voltage and current * Frequency * Voltage, current, and power harmonics * Up to 51st harmonic * Total harmonic distortion (THD) * Phase angle of individual harmonics Specifications Accuracies are stated as (percentage of reading + counts) without probes unless otherwise noted. Input Characteristics Input impedance Voltage rating Volt/Amps/Hertz True-rms voltage (AC+DC) True-rms current (AC+DC) Frequency CF Crest Factor Power W, VA, VAR Reactive Power 1-phase and 3-phase, 3 conductor balanced loads PF Power Factor DPF Displacement Power Factor * Measurements are always automatically recorded to instantly show changes over time * Use cursors to read time and date of sags and swells Hz Frequency fundamental Harmonics Volts, Amps, Watts Specifications are valid for signals with a fundamental between 40 and 70 Hz. Ranges 1 M, 20 pF 600 Vrms, CAT III Accuracy 5.000 V, 50.00 V, 500.0 V, 1250 V* 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA 10.0 Hz to 15.0 kHz 1.0 to 10.0 250 W 2.50 kW, 25.0 kW, 250kW, 2.50 MW, 25 MW, 250 MW, 625 MW, 1.56 GW (2 % + 6 counts) Total Power (4 % + 4 counts) Fundamental Power 0.04 not specified 0.04 0.03 (0.5 % + 2 counts) 0.00 0.00 0.25 0.90 40.0 to to to to to 1.00 0.25 0.90 1.00 70.0 Hz Fundamental 2 to 31st Harmonic 32 to 51st Harmonic Frequency of fundamental Phase K-Factor (Amps & Watts) THD Sags & Swells Recording times (selectable) * Catch voltage transients and waveform distortion down to 40 nS * Catch and save up to 40 transients * Correlate the cause of transients with time and date stamps 40 Hz to 70 Hz Volt & Amps (between Fund. & Harmonic) Watts (between Volt Fund. & Amps Harmonic ) 1.0 to 30.0 0.00 to 99.99 5.000 V, 50.00 V 500.0 V, 1250 V* Arms actual, Arms max, min (AC + DC) Recording Recording times (selectable) 50.00 A, 500.0 A, 5.000 kA, 50,00 kA Transients Minimum pulse width Useful bandwidth input Number of transients Voltage threshold settings Reference signal Vpeak min, Vpeak max at cursor *Rated 600 V CAT II V, A (3 % + 2 counts), W (5 % + 2 counts) V, A (5 % + 3 counts), W (10 % + 10 counts) V, A (15 % + 5 counts), W (30 % + 5 counts) 0.25 Hz 2nd ( 3) ... 51st ( 15) Fund ( 5) ... 51st ( 15) 10 % (3% + 8 counts) 4 min to 16 days Vrms actual, Vrms max, min (AC + DC) Parameters V/A/Hz Power Harmonics Ohms Temperature Scope (1 % + 10 counts) (1 % + 10 counts) (0.5 % + 2 counts) (5 % + 1 count) Readings (2 % +10 counts) Cursor readings (2 % + 12 counts) Cursor Readings Average (2 % +10 counts) 4 min to 16 days Choose one or two parameters from one of the groups below Line Voltage, Current, Frequency Watts, VA, VAR, PF, DPF, Frequency THD, Volts (Fund. & Harmonic), Amps(F&H) Watts(F&H) Freq.(H), %(H) of total, Phase(H), KF Ohms, Diode, Continuity, Capacitance C or F DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor 40 ns DC to 1 MHz (with test leads TL24) 40 20 %, 50 %, 100 %, 200 % above or below reference signal After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting. 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V 5 % of full scale Inrush Current Ranges Current ranges (selectable) 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A Inrush times (selectable) l s, 5 s, 10 s, 50 s, 100 s, 5 min Cursor readings A peak max at cursor 1 and cursor 2 Time between cursors** 4 to 235 pixels Scope, dual channel scope with measurement reading Input impedance Input 1 1 M/12 pF; with BB120: 20 pF Input 2 1 M/10 pF; with BB120: 18 pF Vertical Voltage ranges 50 mV/div to 500V/div Vertical sensitivity, resolution 5 mV/div to 500V/div, 8 bit (256 levels) Bandwidth input 1 (voltage) DC to 20 MHz at inputs, or with VPS40 probe (Opt); 1 MHz with TL24 Leads Bandwidth input 2 (current) DC to 15 kHz at inputs 10 kHz with 80i-500s Current Clamp Coupling DC, AC (10Hz (-3 dB) Horizontal TimeBase modes Normal, roll, single TimeBase ranges 60 s/div to 20 ns/div Sampling rate 25 MS/s Record length (min / max samples) Trigger source Trigger mode Accuracy 5 % of full scale (0.2 % + 2 pixels) 2 pF; with BB120 3 pF 2 pF; with BB120 3 pF (1% + 2 pixels) * Inrush current up to 500A with supplied current probe * Use cursors to measure inrush current timing (0.4 % + 1 pixel) 512 per channel Input 1 or Input 2 or Automatic selection Automatic Connect-and-ViewTM, Free Run, Single Shot. Connect-and-ViewTM Advanced automatic triggering that recognizes signal patterns and automatically adjusts triggering, timebase and amplitude. Automatically displays stable pictures of complex and dynamic signals like motor drive and control signals. Pre-trigger Up to 10 divisions Measurement readings, Volts & Amps (DC, AC, AC + DCrms, Peak max, Peak min, Peak min / max ), per channel selectable Frequency, Duty cycle + or - , Phase, Pulse Width + or -, Crest factor Ohms, Diode, Continuity, Capacitance (0.6 % +5 counts) Ohms 500.0 5.000 k, 50.00 k, 500.0 k, 5.000 M, 30.00 M Diode voltage 0 to 3.000 V (2 % +5 counts) Continuity, shorts > 1 ms Beeper on at < 30 5 , Capacitance 50.00 nF, 500.0 nF, 5.000 F, 50.00 F, (2 % +10 counts) 500.0 F Temperature*** -100.0 C to 400.0 C, (0.5 % +5 counts) -200.0 F to 800.0 F Max current, max open circuit volt. 0.5 mA, < 4 V (all functions above) Memory Number of screens 20 Optical Isolated Interface To printer Supports HP LaserJetTM, DeskJet, Epson FX/LQ and Postscript printers with optional PAC91 Printer Adapter Cable To PC FlukeView(R) Power Quality Analyzer software with PM9080 Interface Adapter included FlukeView(R) Power Quality Software Hardware requirements PC or 100 % compatible with Windows(R) 95, 98, Me, 2000, NT4.0. * Connect-and-ViewTM scope for quick waveform display * 20MHz bandwidth with optional 10:1 voltage probe. 15kHz on current channel with optional current clamp ** 1 pixel = inrush time/250 *** Requires optional temperature accessory * FlukeView(R) Power Quality Analyzer software (included) * Capture measurement screens for professional-looking reports * Log readings to your computer disk drive * Works with Windows word processing, spreadsheet and analysis software * Windows 95 / 98 / Me / 2000 / NT 4.0 General Specifications Power Line voltage adapter/battery charger included Installed battery Rechargeable NiMH pack (4.8v dc) Operating time 4 hours Charging time 7 hours Environmental Temperature 0 C to 50 C (32 F to 122 F) Environmental MIL 28800E, Type 3, Class III, Style B Enclosure IP51 (dust, drip water proof) Mechanical Data Size (H x W x D) 232 x 115 x 50 mm (9.1 x 4.5 x 2 inches) Weight 1.1 kg (2.5 lbs.) incl. battery pack Safety For measurements on 600 Vrms Category III installations, Pollution Degree 2 in accordance with EN 61010-1 ANSI/ISA S82.01-1994 CAN/CSA-C22.2 No. 61010.1-04 Surge protection 6 kV on input 1 and 2 Floating measurements 600 Vrms from any terminal to ground Warranty 3 years parts and labor on Fluke 43B, 1 year on accessories Ordering Information Optional Accessories Fluke 43B Power Quality Analyzer C789 80i-110s i200s i1000s i2000flex Included Accessories C120 TL24 AC20 AC85 TP1 Hard Case Test Leads Industrial Test Clips Large Jaw Alligator Clips Flat-tipped Slim-ReachTM Test Probes TP4 4 mm Round Slim-ReachTM Test Probes i400s 400 A AC Current Clamp OC4USB Optically Isolated USB Interface Adapter BP120MH Rechargeable NiMH Battery Pack (installed) PM8907 Line Voltage Adapter/Battery Charger SW43W FlukeView(R) Power Quality Analyzer Software for Windows Power Quality CD with: * User's manual * Power quality video * Application guide Getting started guide Shielded Banana-to-BNC adapter Soft Carrying Case 100A AC/DC Current Probe AC Current Clamp 1000A AC Current Clamp Flexible 2000A AC Current Probe i3000s Clamp-On AC Current Clamp VPS40 10:1 Voltage Probe BB120 Two Shielded Banana-toBNC Adapters 80TK Thermocouple Module 80T-150U Universal Temperature Probe PAC91 Parallel Printer Adapter TLK225 SureGrip(R) Master Accessory Test Lead Kit TL220 63" Test Lead Set TL221 Extension Lead Set TL223 Electrical Test Lead Set 1 2 43B POWER QUALITY ANALYZER F1 F2 F3 MENU ENTER RECORD SAVE PRINT HOLD RUN Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries (425) 446-5500 or Fax (425) 446-5116 Web access: http://www.fluke.com/ (c)2005 Fluke Corporation. All rights reserved. Trademarks are the property of their respective owners. Printed in U.S.A. 11/2005 1266142 D-ENG-N Rev H Printed on recycled paper.